Weekend Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 70percent

VMware 3V0-32.23 Cloud Management and Automation Advanced Design Exam Practice Test

Demo: 25 questions
Total 86 questions

Cloud Management and Automation Advanced Design Questions and Answers

Question 1

A company has recently completed an audit and has found that there are many virtual machines in their production environment which no longer appear to be in use. To prevent this from happening in the future, the company is deploying vRealize Automation and would like all provisioned VMs to meet the following requirements:

Virtual machines to have a default lease of 90 days but no more than 365 days

Lease policy can be changed

Upon initial lease expiration, the virtual machine should be kept for 10 days, after which they will be destroyed

Which policy design will meet the technical requirements?

Options:

A.

Create a lease policy with the organization scope, setting 90 days lease, 365 total lease, and grace period to 10 and a hard enforcement

B.

Create a lease policy with the project scope, setting 90 days lease, 365 total lease, and grace period to 10 and a hard enforcement

C.

Create a lease policy with the project scope, setting 90 days lease, 365 total lease, and grace period to 10 and a soft enforcement

D.

Create a lease policy with the organization scope, setting 90 days lease, 365 total lease, and grace period to 10 and a soft enforcement

Question 2

Drag and drop each Design Quality from the left into the box corresponding to the correct requirement on the right.

Options:

Question 3

An architect is designing a VMware Aria Automation solution with the following customer requirements:

The solution must be highly available.

The solution must be resilient to a single ESXi host failure.

Which three design decisions would support a customer requirements? (Choose three.)

Options:

A.

Configure a 3-node VMware Identify Manager cluster with an embedded load balancer.

B.

Configure vSphere Distributed Resource Scheduler (DRS) anti-affinity rules for all VMware Aria Automation nodes.

C.

Configure a 3-node VMware Identify Manager cluster with an external load balancer.

D.

Configure a 3-node VMware Aria Automation cluster with an external load balancer.

E.

Configure vSphere Distributed Resource Scheduler (DRS) affinity rules for all VMware Aria Automation nodes.

F.

Configure a 3-node VMware Aria Automation cluster with an embedded load balancer.

Question 4

An organization wants to provide an automated self-service catalog to all departments within the organization. The key stakeholders have asked for the platform to:

Be resilient to component failures.

Each department consume the same on-premises infrastructure.

Restrict visibility and management of virtual machines to only those in their respective departments.

Choose one design decision that will meet the business requirements.

Options:

A.

Deploy multi-node deployment and use projects to separate the departments.

B.

Deploy multi-node deployment and use tenants to separate the departments.

C.

Deploy single node deployment and use projects to separate the departments.

D.

Deploy single node deployment and use tenants to separate the departments.

Question 5

An architect is designing a VMware Aria Operations for Logs cluster for an organization. The organization has the following requirements:

No requirement for archival data

Support a log data retention period of 14 days

How will the log data be handled in this VMware Aria Operations for Logs cluster after the 14-day retention period?

Options:

A.

A variable sized chunk of old log messages is deleted to free up space based on the data age basis.

B.

Old log messages are automatically and periodically retired on a first-come-first-retired basis.

C.

The user needs to manually select and delete specific old log messages to free up space.

D.

Old log messages are automatically and periodically retired on least accessed basis.

Question 6

An architect is designing a VMware Aria Operations for Logs cluster. Due to budget constraints the organization would like to use existing components as much as possible.

What should the architect choose as the load balancing solution for the VMware Aria Operations for Logs cluster?

Options:

A.

Deploy a new external load balancer.

B.

Use an existing external load balancer.

C.

Use both integrated and external load balancers for redundancy.

D.

Use the integrated load balancer.

Question 7

A customer wants to design and deploy Workspace ONE Access to provide an SSO for VMware Aria Suite users. The customer has two data centers with low bandwidth and high latency constraints. The customer requires mitigation against data center failure.

What two design decisions would achieve the customer’s requirements? (Choose two.)

Options:

A.

Deploy SQL Always-on Availability Group cluster across both sites.

B.

Deploy a Workspace ONE Access cluster with internal PostqreSQL in one site.

C.

Deploy a stretched PostgreSQL database cluster across both sites.

D.

Replicate Workspace ONE Access cluster between sites and protect it using VMware Site Recovery Manager.

E.

Deploy a stretched Workspace ONE Access cluster across both sites, connected to stretched database cluster.

Question 8

An architect is evaluating a customer requirement to include Active Directory users as custom resources to be managed by VMware Aria Automation deployments.

What additional component could the architect include in the solution design that will help satisfy the requirement?

Options:

A.

VMware Aria Automation Orchestrator

B.

VMware Aria Automation Pipelines

C.

VMware Identity Manager

D.

VMware Aria Automation LDAP proxy

Question 9

A customer is deploying VMware Aria Operations for Logs in their data centers. The customer has the following:

Three data centers in three geographical locations. Average latency is approximately 20 ms.

L2 stretched networks are not available.

The customer has the following requirement:

Logs collected from any datacenter must be protected against site failure.

Which three design decisions would the architect choose to achieve the requirement? (Choose three.)

Options:

A.

Size a VMware Aria Operations for Logs cluster to accommodate logs from all data centers.

B.

Configure log forwarding from each data center to another one.

C.

Deploy a VMware Aria Operations for Logs cluster in each data center.

D.

Configure forwarding filters to forward logs only once.

E.

Deploy a VMware Aria Operations for Logs stretched across all data centers.

F.

Configure log protection to tolerate one data center failure.

Question 10

An architect is responsible for reviewing the requirements for an existing Cloud Management solution design.

Which requirement would be considered as a functional requirement?

Options:

A.

Thesolution must support the management of workloads within a public cloud.

B.

The solution must meet a Recovery Time Objective of four hours.

C.

The solution must meet a Recovery Point Objective of one day.

D.

Thesolution must meet a monthly uptime ServiceLevel Agreement of 99.5%.

Question 11

A company is planning a logical design for a VMware Aria Automation project. The company has the following requirements.

The company wants to provision virtual machines using intelligent workload placement.

The company wants to use the least administrative effort in their tagging strategy.

The company wants to integrate VMware Aria Automation and VMware Aria Operations.

Developers plan to code locally and centralize template version control.

Which design decision would achieve the requirements?

Options:

A.

Use pre-created vCentertags, configure advanced placement policy, use discovered tags, create a token and add integration using external repository for templates and Sync

B.

Use pre-created vCenter tags, configure spread placement policy, use user defined tags, create a token and add integration using external repository for templates and Sync

C.

Create user defined tags, configure binback placement policy, add integration using internal repository for importing templates and Sync

D.

Create user defined tags, use default placement policy, add integration using external repository for importing templates and Sync

Question 12

A customer is deploying VMware Aria Operations for Logs in their data centers. The customer has the following:

Three data centers in three geographical locations.

Each site has 1,000 logging sources that send events to VMware Aria Operations for Logs.

The customer has the following requirements:

Minimize the resources footprint in the management cluster where VMware Aria Operations for Logs will be deployed.

VMware Aria Operations for Logs must be highly available with no single points of failure.

Logs collected from any data center must be protected against site failure.

Which three design decisions would the architect choose to achieve the requirements? (Choose three.)

Options:

A.

Deploy four VMware Aria Operations for Logs large nodes in a single cluster in each data center.

B.

Deploy nine VMware Aria Operations for Logs medium nodes in a single cluster in each data center.

C.

Configure logs forwarding from each data center to another one.

D.

Configure filters to eliminate forwarding loops between VMware Aria Operations for Logs clusters.

E.

Configure logs forwarding from all data centers to a specific data center.

F.

Configure filters to forward critical logs to central VMware Aria Operations for Logs cluster.

Question 13

An architect is responsible for creating the design for Cloud Monitoring solution that will be used to monitor a VMware software-defined data center.

Given the information from the Service Owner, which two would be considered as non-functional requirements? (Choose two.)

Options:

A.

The solution must support the monitoring of 2000 virtual machines across two physical data center locations.

B.

The solution must support a monthly availability target of 99.9%.

C.

The solution must support a Recovery Time Objective of four hours.

D.

The solution must support the retention of live data for at least 12 months.

E.

The solution must support the ability to scale by 20 percent over the next five years.

Question 14

A customer has an existing deployment of VMware Aria Operations configured with VMware Aria Operations Standard licensing. The customer has decided to buy additional VMware Aria Operations Enterprise licenses to support native public cloud management.

Which options will allow the customer to consume these new Enterprise licenses? (Choose two.)

Options:

A.

Use license groups for Enterprise and Standard licenses within the existing cluster

B.

Purchase the Enterprise Licenses as OSI instead of CPU

C.

Deploy a second VMware Aria Operations cluster

D.

Upgrade all of the Standard licenses to Enterprise

E.

Replace all Standard licenses with vRealize Business for Cloud licenses

Question 15

An architect is completing the physical design for a VMware Aria Operations solution. The customer has only provided the following information for their existing environment:

500 Virtual Machines

Two VMware vCenter Servers

10 VMware vSphere Hosts

20 Datastores

Live data should be stored within the VMware Aria Operations solution for six months

The RTO for all existing management components is four hours

The RPO for all existing management components is one hour

Which assumption could the architect make when designing the solution?

Options:

A.

The Availability Service Level Agreement of the service will be 99.5% measured monthly

B.

The RTO and RPO of the solution will be the same as the existing management components

C.

The solution will deploy Extra Large VMware Aria Operations nodes

D.

The resource profile of a virtual machine will be, on average, 1 vCPU and 2 GB RAM

Question 16

Which two design decisions would an architect document as part of the physical design? (Choose two.)

Options:

A.

VMware Aria Operations Remote Collectors will be deployed in each location.

B.

The solution will use VMware Aria Operations Continuous Availability.

C.

Storage replication for VMware Aria Operations Manager will not be enabled.

D.

The VMware Aria Operations analytics cluster will be comprised of three Large nodes.

E.

vSpherereservation will be used to guarantee a 1:1 vCPU to physical core ratio for data nodes

Question 17

Which three products can be deployed with VMware Aria Suite Lifecycle? (Choose three.)

Options:

A.

VMware Aria Operations

B.

VMware Aria Operations for Applications

C.

VMware Aria Operations for Networks

D.

VMware Aria Operations for Logs

E.

VMware Aria Automation for Secure Clouds

F.

VMware Aria Business Insights

Question 18

An architect is designing an Aria Automation Config (SaltStack Config) for configuration management and looking to integrate with Aria Automation to meet the following conditions:

Multi-Tenancy in Aria Automation

Automated SaltStack Minion agent installation via Cloud Templates resource type

What two aspects does the architect need to include? (Choose two.)

Options:

A.

The integration process will install & enable the SaltStack config service.

B.

The Aria Automation Config (SaltStack Config) service installed via standalone method can be accessed via Aria Automation Service Console.

C.

The Aria Automation Config (SaltStack Config) can be only associated with a single tenancy.

D.

The Aria Automation Config (SaltStack Config) can be associated with multi-tenancy.

E.

Verify Aria Automation administrator credentials and SaltStack Config root-level access.

Question 19

A customer is looking at embarking on their cloud journey and automating their infrastructure deployment using the VMware Cloud Management solution.

The CIO’s goal is to optimize expenditures by making sure that the resources are right-sized, reclaimed, and retired.

Which VMware Cloud Management component will help the customer achieve this?

Options:

A.

Aria Operations for Applications

B.

Aria Automation

C.

Aria Operations for Logs

D.

Aria Operations

Question 20

Which VMware Cloud Management product can help deliver the following use cases:

Continuous operating system compliance enforcement

Automated vulnerability detection and remediation

Options:

A.

VMware Aria Automation Config

B.

VMware Aria Automation Pipelines

C.

VMware Aria Automation for Secure Hosts

D.

VMware Aria Automation for Secure Clouds

Question 21

An architect is designing the VMware Aria Operations component of a Cloud Management solution. The following information has been provided by the customer:

The solution must support the monitoring of virtual machines across three physical sites.

The latency between each physical site is less than 10 ms.

The solution must be resilient to a site failure.

The solution should be resilient to a failure within a site.

Which two design decisions should the architect document to meet the requirements? (Choose two.)

Options:

A.

The VMware Aria Operations cluster should be deployed across all sites usinq vSphere Hiqh Availability

B.

The VMware Aria Operations cluster should be deployed across all sites using Continuous Availability

C.

The VMware Aria Operations cluster should be deployed in each site using High Availability

D.

The VMware Aria Operations cluster should be deployed across all clusters usinq vSphere Fault Tolerance

E.

All VMware Aria Operations components should reside on clusters confiqured for vSphere Fault Tolerance

Question 22

A customer requests a conceptual model for the Cloud Management solution.

What three selections would be included in a conceptual model? (Choose three.)

Options:

A.

VMware Aria Operations for Logs

B.

Logging

C.

Workspace One Access

D.

Monitoring

E.

VMware Aria Automation

F.

Automation

Question 23

An architect has been asked to design a configuration management solution.

Following an initial design workshop with the customer, the following information is known about the existing environment:

The customer already has deployed a VMware Software-Defined Data Center.

The customer is fully licensed for Aria Universal Suite - Standard.

The customer has a corporate policy stating that all user authentication must be completed using Active Directory.

The customer has sufficient budget for additional license purchases (if required).

The following solution requirements have been captured during the design workshop, the solution must:

Be capable of automating the deployment of software to managed virtual machines.

Provide configuration management capabilities.

Provide a centralized Single Sign-On (SSO) solution for all of the cloud management solution.

Which three design decisions would meet the requirement? (Choose three).

Options:

A.

Workspace One Access will be configured to use the system domain for user authentication.

B.

VMware Aria Automation Orchestrator (standalone) will be deployed.

C.

VMware Aria Automation Orchestrator will be configured to use Workspace One Access as its authentication method.

D.

Workspace One Access will be deployed to provide a Single Sign-On solution for all VMware Aria cloud management components.

E.

VMware Aria Automation Config will be deployed.

F.

Workspace ONE Access will be configured to use Active Directory as the authentication solution.

Question 24

Which recommendation should an architect make when designing a highly available VMware Aria Operations cluster?

Options:

A.

Deploy analytics nodes with the same disk size on storage of the same type.

B.

Set Storage DRS to Fully Automated for all VMware Aria Operations Manager analytics nodes.

C.

If the sizing guideline provides several configurations for the same number of objects, use the configuration which has the greatest number of nodes.

D.

Depending on the size and performance requirements for analytics nodes, apply Storage DRS Affinity rules to ensure that nodes are on same datastores.

Question 25

An architect is responsible for creating the design for a Cloud Monitoring solution that will be used to monitor a VMware Software-Defined Data Center.

Which two statements below, provided by the Service Owner, would be considered as non-functional requirements? (Choose two.)

Options:

A.

The solution must support the retention of live data for at least 12 months.

B.

The solution must support a monthly availability target of 99.9%.

C.

The Recovery Time Objective (RTO) of solution is 4 hours.

D.

The solution must be redundant to a minimum of N+1 including during planned maintenance.

E.

The solution must support the monitoring of 1000 virtual machines across two data center locations.

Demo: 25 questions
Total 86 questions